Data Release

Imaging Data

JWST imaging products are coming soon; HST reference products are available through the linked archives.

Spectroscopy

Spectroscopic data processing is in progress.

Photometric Catalog

Photometric catalog products are coming soon.

Point-Spread Functions (PSFs)

PSF products are coming soon.

HST Empirical FWHM (Reference)

Band

F435W

F606W

F775W

F814W

F850LP

F098M

F105W

F125W

F160W

FWHM (arcsec)

0.08

0.08

0.08

0.09

0.09

0.13

0.15

0.16

0.17

Stacked PSFs by Field

Processing Versions

NIRCam

v1.0: Based on the CEERS NIRCam pipeline, with improved WCS calibration and background subtraction.

v1.1: Move the WISP and 1/f correction steps to Stage 2 to allow persistence masking between pipeline stages.

v1.2: Improve the 1/f correction by setting the stripe correction to zero for any row or column in which more than 85% of the pixels are masked. Also improve outlier clipping.

v1.3: Build a reference catalog from F814W and F160W and use it to create the F150W image. Then build a second reference catalog from F150W and F160W to process NIRCam data in the remaining bands.

v1.4: Improve outlier clipping and build the first UDS reference catalog from UKIDSS, F814W, and F160W. Subsequent calibration follows the v1.3 procedure.

v1.4.1: Correct WCS issues in COSMOS and UDS for F090W, F115W, and F200W.

v1.5: Introduce a new WISP subtraction algorithm (currently not applied to the data), update the WISP template, improve mask construction for 1/f removal and background processing, improve outlier clipping, correct a bug in readout-noise construction, and resolve background issues in the files used for the final drizzle.

v1.6: Improve readout-noise treatment and add masks for several outlier regions.

v1.7: Expand the processed dataset to include all observations available as of August 25, 2026. Add a dedicated diagonal-stripe removal procedure for affected exposures, which substantially suppresses the striping artifacts while preserving the underlying science signal. Faint residuals may still be visible in a few strongly contaminated exposures.

v1.0: JWST calibration pipeline v1.12.5; CRDS pmap 1179

v1.1: JWST calibration pipeline v1.12.5; CRDS pmap 1179

v1.2: JWST calibration pipeline v1.12.5; CRDS pmap 1183

v1.3: JWST calibration pipeline v1.12.5; CRDS pmap 1185

v1.4: JWST calibration pipeline v1.12.5; CRDS pmap 1185

v1.5: JWST calibration pipeline v1.13.4; CRDS pmap 1236

v1.6: JWST calibration pipeline v1.16.1; CRDS pmap 1321

v1.7: JWST calibration pipeline v1.16.1; CRDS pmap 1321

MIRI

v1.0: Based on the CEERS MIRI pipeline and the JWST-SPRING NIRCam v1.1 pipeline.

v1.1: Fix a bug that prevented model.meta.wcs, model.meta.wcsinfo, and model.meta.cal_step.tweakreg from being updated in the data model after WCS calibration.

v1.2: Following the NIRCam v1.4 procedure, build a reference catalog from F444W and F160W for MIRI WCS calibration.

v1.3: Correct WCS calibration issues in the pipeline.

v1.3.1: Correct the WCS issue in COSMOS and UDS for F770W.

v1.4: Improve flat-image construction for the detection, DQ, and error arrays; update the strategy to create a flat image every six months; and add an outlier-masking step.

v1.5: Replace flat-file construction with a super-background approach.

v1.7: Expand the processed dataset to include all observations available as of August 25, 2026. Version v1.6 was intentionally skipped to keep the MIRI version numbering consistent with NIRCam.

v1.0: JWST calibration pipeline v1.12.5; CRDS pmap 1177

v1.1: JWST calibration pipeline v1.12.5; CRDS pmap 1179

v1.2: JWST calibration pipeline v1.12.5; CRDS pmap 1185

v1.3: JWST calibration pipeline v1.12.5; CRDS pmap 1185

v1.4: JWST calibration pipeline v1.13.4; CRDS pmap 1216

v1.5: JWST calibration pipeline v1.16.1; CRDS pmap 1321

v1.7: JWST calibration pipeline v1.16.1; CRDS pmap 1321